Emerson Rosemount 8600D Series Reference Manual page 137

Vortex flowmeter
Hide thumbs Also See for Rosemount 8600D Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4860, Rev BC
Example 2 (SI units)
Fluid
Line size
Line pressure
Operating
Temperature
Viscosity
Input
Frequency
K-factor
(compensated)
M
Therefore, an input frequency of 650.00 Hz represents a flow rate of 3446.4 kg/hr in this
application.
For a given input frequency, you may also determine the current output. Use the prior example
with an input frequency of 275 Hz:
URV= 3600 kg/hr
= 10.48 mA
Therefore, an input frequency of 275.00 Hz represents an output current of 10.48 mA.
Electronics verification
= Saturated Steam
= 80 mm.
= 700 kPas
= 170 °F
= 0.015 cp
= 650 Hz
= 10.715 (via Field Communicator or AMS)
= F(Hz) /(K x C
)
16
= 650/{10.715 x (C
= 650/{10.715 x (0.0733811/4.169
= 650/(10.715 x 0.017602
= 3446.4 kg/hr
LRV= 0 kg/hr
 K
F Hz
C
LRV
I
=
16
---------------------------------------------------------- -
URV LRV
275
10.715 0.017602
I
=
--------------------------------------------------------------------------------- -
3600 0
Get other manuals https://www.bkmanuals.com
Appendix C: Electronics verification
URV
= 3600 kg/hr
LRV
= 0 kg/hr
C
= C
16
C-1 on page C-125
Density(
)
= 4.169 kg/cu-mtr
(operating)

/
11

F
(Hz) = 275
in
16
+
4
 0
16
January 2013

Table
/
from
11
)
4
+
129

Advertisement

Table of Contents
loading

Table of Contents