Power supply effect
HART analog
Less than 0.005% of span per volt
A.5

Physical specifications

NACE compliance
Materials of Construction meet NACE material recommendations per MR0175/ISO15156 for use
in H
S containing environments in oil field production. Materials of construction also meet
2
NACE recommendations per MR0103-2003 for corrosive petroleum refining environments.
MR0103 compliance requires Q25 option in model code.
Note
Certificate of compliance for MR0175/ISO15156 requires Q15 as a separate line item.
Electrical connections
1
/
–14 NPT or M20
2
output connections; communicator connections permanently fixed to terminal block.
Non-wetted materials
Housing
Low-copper aluminum (FM Type 4X, CSA Type 4X, IP66)
Paint
Polyurethane
Cover O-rings
Buna-N
Temperature sensor (MTA option)
Type-N Thermocouple
Process-wetted materials
Meter body
CF-8M cast stainless.
Sensor material
CF-3M cast stainless.
Specifications and Reference Data
1.5 conduit threads; screw terminals provided for 4–20 mA and pulse
Get other manuals https://www.bkmanuals.com
Appendix A: Reference Data
January 2013
105