Appendix A

SPECIFICATION

Functional

Physical Specifications

www.rosemount.com
Specifications and
Reference Data
Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-3
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-4
The Rosemount 1595 can be used with Rosemount 1496 Orifice Flange
Unions and Rosemount 1497 Meter Sections. For product offering see
document number 00813-0100-4792.
Service and Flow Range
Liquid, gas or vapor turbulent flow, for pipe Reynold's Numbers greater than
2,000.
Pipe Sizes
2 to 24-in. (50 to 600 mm). Contact Emerson Process Management for other
pipe sizes.
Operating Temperature Limits
-100 to 700 °F (-73 to 370 °C) (Contact Emerson Process Management for
temperatures above 700 °F)
Maximum Working Pressure
• Flange rating per ANSI B16.5.
Materials of Construction
Orifice Plate
• 316/316L Stainless Steel
Flange Mounting Hardware
• The 1595 can be tailored for use in conjunction with the Rosemount 1496
Flange Union and, if required, the Rosemount 1497 Meter Section. See
the Product Data Sheet 00813-0100-4792 for more information regarding
the Rosemount 1496 and 1497.