■Heat-sink going out attachment(simple type)
To install a standard VF-P7 designed for 200V-37kW motor or larger or 400V-45kW motor or
larger, you can choose a one from next two forms.
(1) Normal attachment (Whole the inverter is in the cabinet)
(2) Heat-sink going out (the cabinet) attachment(simple type)
Heat-sink going out attachment reduces the generation of heat inside the cabinet.
When you carry out heat-sink going out attachment, please change the position of the
attachment ornaments (hanging hole) of the inverter according to the following figure.
(1) Normal attachment
ornament
Take this
off (*1)
(*1) Metallic ornaments with the hanging hole are attached only in the following models.
   
200V class: Applicable motor capacity is 75kW or larger
400V class: Applicable motor capacity is 110kW or larger
(2) Heat-sink going out attachment
(simple type)
ornament
Take this
off (*1)
Change the
position
Change the position
Change the position
Change the position
A-18