Specifications

Figure A.1 shows the connector locations for the AEC. The following
tables provide the pin numbers and their respective descriptions.
Plug A
10 = Clock +
9 = Data +
8 = Shield
7 = Transducer Power Return
6 = Shield
Plug A
8 = Reference +
7 = N/O Fault Relay Contact
6 = N/C Fault Relay Contact
5 = Shield
Plug A
12 = Z -
11 = B -
10 = A -
9 = Strobe -
8 = Reference Shield Input
7 = Reference - Input
SSI Connector
Plug B
5 = Clock -
4 = Data -
3 = Transducer Power +5V DC
2 = Transducer Power +15V DC
1 = Transducer Power +24V DC
Control Connector
Plug B
4 = Reference -
3 = N/O Fault Relay Contact
2 = N/C Fault Relay Contact
1 = Shield
Encoder Connector
Plug B
6 = Z +
5 = B +
4 = A +
3 = No Connection
2 = Strobe +
1 = Reference + Input