The Ssi Connector - Allen-Bradley 4100-AEC Installation And Setup Manual

Absolute encoder converter
Table of Contents

Advertisement

22
Installation & Hook-Up
Publication 4100-5.2 - March 2000
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
7. Use the screwdriver to tighten the clamping screw to the proper
torque (0.25 N-m/2.2 in-lb.).
8. Verify that the cable lead does not pull out of the terminal.
9.
Cable Leads
If the cable lead:
Pulls out of the terminal
Does not pull out of the
terminal
The function of these connectors, their pinouts, and names are
defined in the following sections.

The SSI Connector

The SSI connectors are used to connect the absolute transducer to the
AEC. The pin layout and functionality for this connector are as
follows.
SSI Connector Pin Functions
Pin Number
1
2
3
4
5
6
7
8
9
10
The following is the connector pin numbering scheme for the SSI
connector as viewed with the AEC mounted in its normal position.
Do this:
Repeat steps 3 through 9
again
Repeat steps 3 through 9 for
the next terminal
SSI Input
Pin Function
Transducer Power +24V DC
Transducer Power +15V DC
Transducer Power +5V DC
Data -
Clock -
Shield
Transducer Power Return
Shield
Data +
Clock +