Einstellung Dach - Und Wannenprofil (Tas-Uni-Dp); Adjustment Roof Profile - probst TAS-UNI-450 Operating Instructions Manual

Hide thumbs Also See for TAS-UNI-450:
Table of Contents

Advertisement

Available languages

Available languages

Assembly and adjustments
Einstellung Dach – und Wannenprofil (TAS-UNI-DP)
3.2
With the adjustable adapter TAS-UNI-DP (2000 mm) any
roof or pan profile can be adjusted (+/- 4 % with scale) to
prepare any roof or pan profiles.
Screw the nuts on the inner side at the TAS-UNI-DP
slope (%) for roof profile→ Figure 2 (see also Figure A on
following page).
Screw the nuts on the outer side at the TAS-UNI-DP
slope (%) for pan profile→ Figure 3 (see also Figure B on
following page).

3.2.1 Adjustment roof profile

Loosen both nuts (2) on the outer side at the TAS-UNI-DP. → Figure 1
Adjust the slope (e.g. 1%) with the both nuts (3) on the inner side at the TAS-UNI-DP. → Figure 2
Slope (e.g. 1%) is viewable and adjustable on the scale (4) and indicator (5). → Figure 3
1 scale line on the scale (4)
Der angezeigte Neigungswert (%) auf der Skala dient nur als Orientierung.
Die tatsächliche Neigung (%) muss unbedingt am Planum nachgemessen werden!
Siehe Darstellung A und A1 auf nachfolgenden Seiten.
Fig. 1
51000100 / 51000101
Fig. 1
0,5 % slope. → Figure 3
(2)
TAS-UNI-
DP
Fig. 2
Fig. 2
(3)
(3)
10 / 19
Fig. 3
(5)
Fig. 3
(4)
GB