Download Print this page

Crash Codes For Type 102 Messages - IBM 6611 Pocket Manual

Network processor

Advertisement

1. Press Reset until a flashing 888 appears on the
3-digit display.
2. When a flashing
888 appears, go to "Reading
Flashing 888 Numbers" on page A-3.
3. If a flashing 888 does not appear, you should
consider the numbers as steady numbers.
Record 1 01-xxx where xxx is the steady
number displayed on the 3-digit display.
Crash Codes for Type 102 Messages
This section contains a list of the crash codes that
are part of a type 102 message. See "Reading Type
102 Messages" on page A-3 for instructions about
how to read a crash code from the 3-digit display.
The crash codes are:
000
Unexpected system interrupt.
200
System check because of a memory bus
error.
201
System check because of a memory timeout.
202
System check because of a memory card
failure.
203
System check because of an address that is
out of range.
204
System check because of an attempt to write
to ROS.
205
System check because of an unrecoverable
address parity.
206
System check because of an unrecoverable
ECC error.
207
System check because of an unidentified
error.
300
Data storage interrupt from the processor.
32x
Data storage interrupt because of an 1/0
exception from 10CC.
38x
Data storage interrupt because of an 1/0
exception from SLA.
Appendix A. 3-Digit Display Codes