ACME XP-5000WZ User Manual page 32

Table of Contents

Advertisement

D. The lamp is cutting out intermittently
1. The lamp is not working well. Check the mains voltage either too high or too low.
2. Internal temperature may be too high. Check if replacement of fan is needed on the head.
E. If The pan belt is broken
1. Turn off the mains power.
2. Loosen all the screws (AB),open the cover (C).
3. Loosen the screws (D).
4. Unplug all the connect wires over the belt.
5. Change a new belt (E), put the belt around the axis gear and motor gear.
6. Plug all the connect wires back upon the belt.
7. Tighten all the screws.
D
F. If The tilt belt is broken
1. Turn off the mains power.
2. Loosen all the screws (AB).
3. Loosen the screws (C) that fix the bridge.
4. Change a new belt (D). Please adjust the tension of the belt properly. Note: do not fix the belt too
tight as it is can easily rupture.
5. Reverse the procedures from step 3 to 2.