Start Of Diesel Engine - Fayat Group DYNAPAC CA25 Instruction Manual

Hide thumbs Also See for DYNAPAC CA25:
Table of Contents

Advertisement

12
2
5
Fig. Control panel:
2.
Emergency stop;
12. Parking brake;
5.
Forward/reverse lever;
12
Fig. Control panel:
12.
Parking brake
26. Speed selector.
10-03-2022
Operation – Start-up

Start of diesel engine

Make sure that the emergency stop (2) is pulled out.
Make sure that the parking brake switch (12) is activated.
Set the forward/reverse lever (5) in neutral. The engine can
only be started when the lever is in neutral.
Set Speed selector (26) at the position for idle running, low.
Warmup: turn key to position II. When the heating symbol
on the display turns off, turn the starting switch to position
3c. As soon as the engine has started, let the starting
switch go.
Do not run the starter motor for too long. If the
engine does not start, wait a minute or so before
trying again.
Idle the engine for few minutes until it is warm longer if the
ambient temperature is less than +10°C (50°F).
At temperatures below 0°C (32°F) the diesel engine and
26
hydraulic system should be warmed up for at least 15
minutes.
When activating and driving the machine in low
temperature, remember that the oil has the same
temperature and the breaking distances are
longer than after it reaches its normal working
temperature.
Ensure good ventilation (air extraction) if the
diesel engine is run indoors. Risk of carbon
monoxide poisoning.
4812331840EN
Operation – Start-up
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynapac ca30Dynapac ca3510300181kle000072

Table of Contents