Attaching An E1H/E2H To The Pedestal - Danfoss VLT HVAC Drive FC 102 Operating Manual

355-800 kw, enclosure sizes e1h-e4h
Hide thumbs Also See for VLT HVAC Drive FC 102:
Table of Contents

Advertisement

Operating Guide | VLT® HVAC Drive FC 102
Example:
Illustration 9:
Pedestal to Floor Mounting Points (Circled)

4.8.2 Attaching an E1h/E2h to the Pedestal

Prerequisites:
The pedestal must be secured to the floor using 6 bolts before installing the enclosure.
Procedure
1. Lift the drive and position it on the pedestal. There are 2 bolts in the rear of the pedestal that slide into the 2 slotted holes in the
rear of the enclosure. Position the drive by adjusting the bolts up or down. Loosely secure with 2 M10 nuts and locking brackets.
See
illustration
10.
2. Verify that there is 225 mm (9 in) top clearance for air exhaust.
3. Verify that the air intake at the bottom front of the unit is not obstructed.
4. Around the top of the pedestal, secure the enclosure using 6 M10x30 fasteners. Refer to
until all bolts are installed.
5. Fasten each bolt securely and torque to 19 Nm (169 in-lb).
6. Torque the 2 M10 nuts at the rear of the enclosure to 19 Nm (169 in-lb).
Danfoss A/S © 2020.01
Mechanical Installation
illustration
11. Loosely tighten each bolt
AQ275556502253en-000101 / 130R0706| 27

Advertisement

Table of Contents
loading

Table of Contents