4. Attach each wall shield to the back of the corresponding flue riser using the provided #10 sheet metal screws.
5. Connect the top side edges of adjoining flue risers using the provided small plates and screws.
6. If tubed shelves were installed, place the tubes in place in the shelf brackets.
7. If sloped enclosures were ordered (for flue-mounted salamander broilers and/or cheese melters), install them at
this time.
S
C
TEP 6:
ONNECT
I
H
NDUCTION
OBS)
A wiring diagram is located behind the kick panel of the oven-base ranges. Be sure that the input voltage and phase
match the requirements shown on the serial plate.
Oven-base ranges ordered with a 115V, 60Hz, single-phase electrical rating are factory-supplied with a three-wire cord
with a three-prong plug that fits any standard three-prong grounded receptacle. Each standard oven requires a 15 ampere
supply, while each convection oven requires a 20 ampere supply.
Oven-base ranges ordered with a 208/236V, 60Hz, single- or three-phase electrical rating are factory-equipped with a
two-pole terminal block located behind cover plate located on the rear of the unit. To connect the supply wires, remove
the cover plate. Route the supply wires and the grounding wire through the strain relief fitting to the terminal block. Insert
the supply wires, one each, into the two poles of the terminal block and tighten the screws. Insert the ground wire into the
grounding lug and tighten the screw. Re-attach the cover plate.
Three phase units are wired as above, using only two supply wires. The third wire is not used and must be properly
terminated.
All units are shipped wired as specified by factory order. Conversion between single-phase and three-phase can be
accomplished by referring to phase loading and line amperes chart on the wiring diagram for wire size and ampere
requirements.
For units equipped with Induction hobs, consult the data label on the unit for voltage and amperage information. "A" model
units my have a separate power cord for the lower ovens and a terminal block for the induction hobs.
S
C
TEP 7:
ONNECT
If the sectional range is being installed at over 2,000 feet altitude and that information was not specified when ordered,
contact the appropriate authorized Southbend Service Representative or the Southbend Service Department. Failure to
install with proper orifice sizing will result in poor performance and may void the warranty.
The sectional range is design-certified for operation on natural or propane gases. The sectional range is shipped
configured and adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1
on page 3). Connect the sectional range ONLY to the type of gas for which it is configured and adjusted.
Minimum supply pressure is 7" W.C. for natural gas, 11" W.C. for propane. An external pressure regulator and shut off
valve are provided. If using a flexible-hose gas connection, the I.D. of the hose must not be smaller than the connector on
the sectional range, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent undue strain
on the gas connection.
If applicable, the vent line from the gas pressure regulator shall be installed to the outdoors in accordance with local
codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code,
CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for
satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and
affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold pressure.
The supply line to the sectional range should be no smaller than the inside diameter of the pipe on the sectional range to
which it is connected.
ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY SOAPY
WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. ALL
CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE APPLIANCE HAS BEEN PUT INTO OPERATION.
TEST PRESSURE SHOULD NOT EXCEED 14" W.C
OWNER'S MANUAL 1185836 REV 9 (10/16)