Sinclair SDV 6 Service Manual page 38

Full dc inverter systems

Advertisement

Table 4.2: Indoor unit Parameter Settings(continues)
Parameter
Parameter Name
Code
Long-distance alarm
N40
function setting
N41
Turbo
N42
Sterilization function
N43
Sterilization setting
N44
Silent mode setting
N45
ECO
Drying time at
N46
self-cleaning
Mildew-proof fan
operation duration
N47
(power off in cooling/dry
mode, except power off
due to faults)
N48
Dirt proof for ceiling
N49
Condensation proof
N50
Human Detect Sensor
Setting temperature
N51
adjustment interval when
unattended
Setting maximum
N52
temperature adjustment
when unattended
Parameter
Default
Range
Value
00/01
00
00
00/01
00/01
00
00/01/02
00
00/01
00
00/01
01
0/1/2/3
0
00/01/02/03
00
00/01
00
00/01
00
00/01/02
01
00/01/02/03/04/
00
05
00/01/02/03
00
Remarks
00: Alarm when closed
01: Alarm when open
00: Off
01: On (Rapid cooling/Rapid heating)
00: No sterilization function (default)
01: Plasma disinfection
00: Auto on
01: Forced on
02: Forced off
00: Off
01: On
00: Off
01: On
0: 10 min
1: 20 min
2: 30 min
3: 40 min
00 - 40s
01 - 120s
02 - 300s
03 - 600s
00: Invalid
01: Valid
00: Invalid
01: Valid
00: Invalid
01: Used to adjust the set temperature when
unattended
02: Used to turn off the unit when unattended
00: 15 min
01: 30 min
02: 45 min
03: 60 min
04: 90 min
05: 120 min
00: 1°C
01: 2°C
02: 3°C
03: 4°C
35