Sinclair SDV 6 Service Manual page 39

Full dc inverter systems

Advertisement

Table 4.2: Indoor unit Parameter Settings(continues)
Parameter
Parameter Name
Code
Stop delay when
N53
unattended
ETA function
N54
setting
Energy rating of cooling
N55
ETA
Energy rating of heating
N56
ETA
On-site fan speed
N57
adjustment factor
Initial static pressure
N58
detection
Filter ending - initial static
N59
pressure setting
Ambient temperature
N60
when preheating is
turned on
N61
Reserved
N62
Reserved
N63
Reserved
N66
Auto Dry Function
Auto Dry Target relative
N67
humidity
Refrigerant leakage fault
N68
reset
Notes:
If use other controllers, parameter settings need refer to the corresponding manual.
36
Parameter
Default
Range
Value
00/01/02/03/04/
01
05
01
00/01
00/01/02
00
00/01/02
00
00/01/02/03/04/
00
05/06
00/01
00
00/01/.../19
00
00/01/02
00
00/01
00
40%/41%/42%/...
65%
.../7 65% 0%
00/01
00
Remarks
00: 15 min
01: 30 min
02: 45 min
03: 60 min
04: 90 min
05: 120 min
00: Off
01: On
00: Level 1
01: Level 2
02: Level 3
00: Level 1
01: Level 2
02: Level 3
00: 1
01: 1.05
02: 1.1
03: 1.15
04: 0.95
05: 0.9
06: 0.85
00: Not reset
01: Reset
00-10Pa/ 01-20Pa/
02~19-30Pa ~200Pa
00: 5°C
01: 0°C
02: (-5)°C
--
--
--
00: Invalid(default)
01: Valid
Note: Only applicable to operations in Cool or Auto mode
00: Not reset;
01: reset