Fan motor and pump motor direction
Once the electrical connection of the burner is performed, remember to check the rotation of the motor. The motor should rotate accor-
ding to the arrow shown on the next picture. In the event of incorrect rotation reverse the three-phase supply and check again the rota-
tion of the motor.
NOTE: burners are supplied for three-phase 400 V supply, and in the case of three-phase 230 V supply it is necessary to modify the
electrical connections inside the terminal box of the electric motor and replace the thermal cutout relay.
Connecting the oil heating resistors
2.4 - 4.5 kW
400 V
R1
L2
L1
R2
R3
L3
18 - 24 kW
400 V
L1
R1
R6
R2
R5
R3
R4
L3
C.I.B. UNIGAS - M039126CE
230V
R1
L2
L1
R2
R3
L3
Fig. 8
230V
L1
R1
R2
R6
L2
L2
R3
R5
R4
L3
Fig. 10
8 - 12 kW
400 V
R1
L1
R2
L2
R6
R3
R5
R4
L3
Fig. 9
ELECTRIC MOTOR CONNECTION
400 V
W2
U2
V2
U1
V1
W1
L1
L2
L3
Fig. 11