submenu CnF - configuration parameters group :
Menu
Parameter
Description
CnF
CONFIGURATION
AI1
Analog Input 1
A1P
Probe 1 Presence
A1C
Calibration Probe 1
AI2
Analog Input 2
A2P
Probe 2 Presence
A2C
Calibration Probe 2
AI3
Analog Input 3
A3P
Probe 3 Presence
A3L
Min. Value conversion AI3
A3H
Max. Value conversion AI3
A3C
Calibration Probe 3
AI4
Analog Input 4
A4P
Probe 4 Presence
A4L
Min. Value conversion AI4
A4H
Max. Value conversion AI4
A4C
Calibration Probe 4
dI
Digital input
dI1
Input 1 polarity (Pump)
dI2
Alarm polarity from input 2
dI3
Alarm polarity from input 3
dI4
Alarm polarity from input 4
dI5
Alarm polarity from input 5
dI6
Alarm polarity from input 6
Digital output
dI
Alarm and Warning
dO5
Polarity output Warning
dO6
Polarity output Alarm
SIC
Safety probe
SIp
Selection of safety probe
SyS
Syistem
dSA
display A output
dSb
display B output
PAS
Password
PL1
Password level 1
PL2
Password level 2
PL3
Password level 3
Additional description
This parameter enables or disables the
probe
Don't modify it
This parameter enables or disables the
probe
Don't modify it
This parameter enables or disables the
probe
Don't modify it
Don't modify it
Don't modify it
This parameter enables or disables the
probe
Don't modify it
Don't modify it
Don't modify it
Change type of digital input ( NC o NO)
Change type of digital input ( NC o NO)
Change type of digital input ( NC o NO)
Change type of digital input ( NC o NO)
Change type of digital input ( NC o NO)
Change type of digital input ( NC o NO)
Change type of digital input ( NC o NO)
Change type of digital input ( NC o NO)
Probe which also activates the relay
Warning (ns. KTRS)
Probe temperature or set-point to be
displayed in the left display
Probe temperature or set-point to be
displayed in the right display
Min
Max
Default
0
1
1
-20,0
20,0
0,0
0
1
1
-20,0
20,0
0,0
0
4
1
-999,9
999,9
0,0
-999,9
999,9
30,0
-20,0
20,0
0,0
0
4
1
-999,9
999,9
0,0
-999,9
999,9
30,0
-20,0
20,0
0,0
0
1
1
0
2
2
0
2
2
0
2
2
0
2
2
0
2
2
0
1
0
0
1
0
0
4
4
0
8
1
0
8
3
0
9999
0
0
9999
0
9999
Visibility
Password
U.M.
condition
level
0
1
2
°C
A1P >0
3
1
2
°C
A2P >0
3
1
2
A3P >2
3
A3P >2
3
°C
A3P >0
3
1
2
A4P >2
3
A4P >2
3
°C
A4P >0
3
1
3
2
2
2
2
2
1
3
3
1
3
0
3
3
1
1
2
3
COD. M12924CA Rel. 0.5 03/2016