Screw the pump cap as far as it will go.
4.
The handle on the pump cap must be in a vertical
position.
19 Troubleshooting
You can rectify minor faults on your appliance yourself.
Read the troubleshooting information before contacting
after-sales service. This will avoid unnecessary costs.
WARNING ‒ Risk of electric shock!
Improper repairs are dangerous.
Repairs to the appliance should only be carried out
▶
by trained specialist staff.
Only use genuine spare parts when repairing the
▶
appliance.
If the power cord of this appliance is damaged, it
▶
must be replaced by the manufacturer, the manufac-
turer's Customer Service or a similarly qualified per-
son in order to prevent any risk.
19.1 Malfunctions
Fault
The display goes out
and Start/Reload
flashes.
"E:30 / -80"
Cause and troubleshooting
Energy-saving mode is active
Press Start/Reload
▶
a The symbol lights up again.
Drain pipe or water outlet hose is blocked.
Clean the drain pipe and the water outlet hose.
▶
Drain pipe or water drain hose is caught or jammed.
Ensure that the drain pipe and water drain hose are not kinked or trapped.
▶
The water outlet hose is connected too high.
Install the water outlet hose at a maximum height of 1 metre.
▶
Unapproved extension installed on the water drain hose.
Remove any unapproved extensions from the water hose.
▶
→ "Connecting the appliance", Page 8
Drain pump is blocked.
→ "Cleaning the drain pump", Page 19
▶
Pump cover is not correctly assembled.
Correctly assemble the pump cover.
▶
The pump cap is not fully screwed in.
Ensure that the pump cap is screwed in all the way into the appliance. The handle on the
▶
pump cap must be in a vertical position.
Insert and close the maintenance flap.
5.
.
Troubleshooting en