Can be selected using Pr. 75 Reset selection/disconnected PU detection/PU stop selection.
∗2
Can be selected using Pr. 122 PU communication check time interval, Pr. 336 RS-485 communication check time interval, Pr. 548 USB communication check time
interval.
∗3
As controlled by the communication option.
∗4
In the PU JOG operation mode, operation is always stopped when the PU is disconnected. Whether fault (E.PUE) occurrence is allowed or not is as set in
Pr. 75 Reset selection/disconnected PU detection/PU stop selection.
∗5
When Pr. 550 NET mode operation command source selection = "2" (PU connector valid) or Pr. 550 NET mode operation command source selection = "9999" and the
communication option is not fitted.
∗6
When Pr. 550 NET mode operation command source selection = "0" (communication option valid) or Pr. 550 NET mode operation command source selection = "9999"
and the communication option is fitted.
Selection of operation mode and operation location