Parameter list
Func-
Parameter
Name
tion
Reset selection/disconnected PU
75
detection/PU stop selection
77
Parameter write selection
78
Reverse rotation prevention selection
79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Motor rated voltage
84
Rated motor frequency
Speed control gain (advanced
89
magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
96
Auto tuning setting/status
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting
124
PU communication CR/LF selection
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
58
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 3, 14 to 17
1
14
176
0, 1, 2
1
0
179
0, 1, 2
1
0
180
183,
0, 1, 2, 3, 4, 6, 7
1
0
193
76, 79,
0.1 to 15kW, 9999
0.01kW
9999
82,
113
76, 79,
2, 4, 6, 8, 10, 9999
1
9999
82,
113
0 to 500A (0 to ****),
0.01A (1)
9999
113
∗5
9999
∗5
200V/400V
0 to 1000V
0.1V
113
∗7
10 to 120Hz
0.01Hz
60Hz
113
0 to 200%, 9999
0.1%
9999
79
0 to 50Ω (0 to ****) ,
0.001Ω (1)
9999
113
∗5
9999
∗5
0 to 50Ω (0 to ****) ,
0.001Ω (1)
∗5
9999
113
9999
∗5
0 to 1000mH (0 to 50Ω,
0.1mH
9999
113
0 to ****), 9999
(0.001Ω, 1)
∗5
∗5
0 to 1000mH (0 to 50Ω,
0.1mH
9999
113
0 to ****) , 9999
(0.001Ω, 1)
∗5
∗5
0 to 100% (0 to 500Ω, 0
0.1%
9999
113
to ****) , 9999
(0.01Ω, 1)
∗5
∗5
113,
0, 1, 11, 21
1
0
154
203,
0 to 31 (0 to 247)
1
0
220
203,
48, 96, 192, 384
1
192
220
0, 1, 10, 11
1
1
203
203,
0, 1, 2
1
2
220
0 to 10, 9999
1
1
204
204,
0, 0.1 to 999.8s, 9999
0.1s
0
220
0 to 150ms, 9999
1
9999
203
0, 1, 2
1
1
203
0 to 400Hz
0.01Hz
60Hz
171
0 to 400Hz
0.01Hz
60Hz
171
Customer
Parameter
Remarks
Setting
75
77
78
79
80
81
82
83
84
89
90
91
92
93
94
96
117
118
119
120
121
122
123
124
125
126
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
AD MFVC
AD MFVC
AD MFVC
4B
CB
0
4D
CD
0
∗4
4E
CE
0
4F
CF
0
∗4
50
D0
0
×
×
51
D1
0
×
52
D2
0
53
D3
0
×
×
54
D4
0
×
×
59
D9
0
5A
DA
0
×
5B
DB
0
5C
DC
0
×
5D
DD
0
×
5E
DE
0
×
60
E0
0
11
91
1
12
92
1
13
93
1
14
94
1
15
95
1
16
96
1
17
97
1
18
98
1
19
99
1
1A
9A
1