Parameter list
Func-
Parameter
Name
tion
C0
FM terminal calibration
(900)
∗6
C1
AM terminal calibration
(901)
∗6
C2
Terminal 2 frequency setting bias
(902)
frequency
∗6
C3
Terminal 2 frequency setting bias
(902)
∗6
125
Terminal 2 frequency setting gain
(903)
∗6
frequency
C4
Terminal 2 frequency setting gain
(903)
∗6
C5
Terminal 4 frequency setting bias
(904)
frequency
∗6
C6
Terminal 4 frequency setting bias
(904)
∗6
126
Terminal 4 frequency setting gain
(905)
frequency
∗6
C7
Terminal 4 frequency setting gain
(905)
∗6
C22 to C25
Parameter for manufacturer setting. Do not set.
(922 to 923)
990
PU buzzer control
991
PU contrast adjustment
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
Pr.CH
Initial value change list
∗1
Differ according to capacities.
6%: FR-E720-050 or less, FR-E740-026 or less
4%: FR-E720-080 to175, FR-E740-040 to 095
3%: FR-E720-240 and 330, FR-E740-120 and 170
2%: FR-E720-470 and 600
∗2
Differ according to capacities.
5s: FR-E720-175 or less, FR-E740-095 or less
10s: FR-E720-240 and 330, FR-E740-120 and 170
15s: FR-E720-470 or less
∗3
Differ according to capacities.
6%: FR-E720-008 and 015
4%: FR-E720-030 to 330, FR-E740-016 to 170
2%: FR-E720-470 and 600
∗4
Write is disabled in the communication mode (network operation mode) from the PU connector.
∗5
The range differs according to the Pr. 71 setting.
∗6
The parameter number in parentheses is the one for use with the operation panel (PA02) for the FR-E500 series or parameter unit (FR-PU04/FR-PU07).
∗7
The initial value differs according to the voltage class. (200V class, 400V class)
70
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
152
152
0 to 400Hz
0.01Hz
0Hz
171
0 to 300%
0.1%
0%
171
0 to 400Hz
0.01Hz
60Hz
171
0 to 300%
0.1%
100%
171
0 to 400Hz
0.01Hz
0Hz
171
0 to 300%
0.1%
20%
171
0 to 400Hz
0.01Hz
60Hz
171
0 to 300%
0.1%
100%
171
0, 1
1
1
263
0 to 63
1
58
263
0, 1
1
0
264
0, 1
1
0
264
0, 1
1
0
266
265
Customer
Parameter
Remarks
Setting
C0
(900)
C1
(901)
C2
(902)
C3
(902)
125
(903)
C4
(903)
C5
(904)
C6
(904)
126
(905)
C7
(905)
C22 to C25
Parameter for manufacturer setting. Do not set.
(922 to 923)
990
991
Pr.CL
ALLC
Er.CL
Pr.CH
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
AD MFVC
AD MFVC
AD MFVC
5C
DC
1
5D
DD
1
5E
DE
1
5E
DE
1
5F
DF
1
5F
DF
1
60
E0
1
60
E0
1
61
E1
1
61
E1
1
5A
DA
9
5B
DB
9
Parameter list
Parameter
Copy
Clear
All clear
×
×
×
×
×
×
×
×
×
×
×
4

Advertisement

Table of Contents
loading