Parameter
Parameter
Register
41000 to
Refer to the parameter list (page
0 to 999
41999
54) for the parameter names.
Terminal 2 frequency setting
C2(902)
41902
bias frequency
Terminal 2 frequency setting bias
42092
(Analog value)
C3(902)
Terminal 2 frequency setting bias
43902
(Terminal analog value)
Terminal 2 frequency setting gain
125(903)
41903
frequency
Terminal 2 frequency setting gain
42093
(Analog value)
C4(903)
Terminal 2 frequency setting gain
43903
(Terminal analog value)
Terminal 4 frequency setting bias
C5(904)
41904
frequency
Terminal 4 frequency setting bias
42094
(Analog value)
C6(904)
Terminal 4 frequency setting bias
43904
(Terminal analog value)
Terminal 4 frequency setting
126(905)
41905
gain frequency
Terminal 4 frequency setting gain
42095
(Analog value)
C7(905)
Terminal 4 frequency setting gain
43905
(Terminal analog value)
Faults history
Register
40501
Fault history 1
40502
Fault history 2
40503
Fault history 3
40504
Fault history 4
40505
Fault history 5
40506
Fault history 6
40507
Fault history 7
40508
Fault history 8
Fault code list
Data
Definition
No fault
H00
present
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT
H31
E.THM
H40
E.FIN
H52
E.ILF
* Refer to page 271 for details of fault definition.
Parameter Name
Definition
Read/write
Read/write
Data
Definition
H60
E.OLT
H70
E.BE
H80
E.GF
H81
E.LF
H90
E.OHT
HA1
E.OP1
HB0
E.PE
HB1
E.PUE
HB2
E.RET
HB3
E.PE2
HC0
E.CPU
HC5
E.IOH
Communication operation and setting
Read/
Write
The parameter number + 41000 is the register
Read/write
number.
Read/write
Read/write The analog value (%) set to C3 (902) is read.
The analog value (%) of the voltage (current)
Read
applied to the terminal 2 is read.
Read/write
Read/write The analog value (%) set to C4 (903) is read.
The analog value (%) of the voltage (current)
Read
applied to the terminal 2 is read.
Read/write
Read/write The analog value (%) set to C6 (904) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write The analog value (%) set to C7 (905) is read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Being 2 bytes in length, the data is stored as
Read
"H00
".
Read
The error code can be referred to in the low-order 1
Read
byte.
Read
Performing write using the register 40501 batch-
Read
clears the faults history.
Read
Set any value as data.
Read
Data
Definition
HC7
E.AIE
HC8
E.USB
HD8
E.MB4
HD9
E.MB5
HDA
E.MB6
HDB
E.MB7
HF1
E.1
HF6
E.6
HF7
E.7
HFD
E.13
Remarks
Remarks
231
4