Advanced Programming

There are several Advanced Programming options. The following Table identifies each option and when it is used.
Advanced
Setting
Option
A1
Lockout
Code (Optional)
A2
Low Level Alarm
Time
A5
Active Alarm
A7
Constant Alarm
Output on Fault
Firmware 5.01 and later
A8
4 Digit Hour Off
Time
Firmware 5.04 and later
A10
Low Level Reset
Upon power ON
A11
Warning OFF
through alarm
relay
Firmware 5.06 and later
A12
Prelube
Sequences
A13
MM:SS Off Time
332298M
Format/ Description
Secures setup modes with
PIN
MM:SS (minutes:seconds)
sets amount of time
between Low Level Warning
to Low Level Fault.
Default = 3 minutes
Changes alarm output
behavior.
Default = OFF
Changes alarm output
behavior.
Default = OFF
Changes maximum OFF
time.
Default = OFF
Changes low level fault
upon power ON.
Default = OFF
Changes alarm output
behavior.
Default = OFF
Changes the number of the
Prelube sequences.
Changes the OFF time
programming from HH:MM
to MM:SS
Default = OFF
Why Use This?
Prevents unauthorized users to adjusting settings.
To accommodate most lubrication situations, a
conservative amount of time is programmed
between the low level warning and fault to help
protect unit from running dry. If necessary the
amount of time the unit runs before stopping due to
a low level fault can be adjusted.
Uses alarm output to determine if a unit has an
alarm AND/OR loses power.
The output turns ON when power is applied. It turns
OFF when power is lost or an alarm occurs.
Normal operation (OFF) will only activate alarm
output in an alarm condition when power is on.
Can change (set to ON) to activate alarm with power
ON and deactivate with power OFF OR warning.
Used to manage power outage.
This function changes the behavior of the alarm
output in a fault from either toggling once every
second or steady on.
This function changes OFF time from HH:MM to
HHHH. It allows a maximum of 9999 hours of OFF
time.
This function changes the behavior of the low level
fault upon power ON.
This function changes the behavior of the alarm
output in a warning condition to always OFF.
This function changes the behavior of the prelube
function to add more lubrication sequences upon
pump start up.
This function changes the programming of the OFF
time.
Advanced Programming
31