Advanced Programming

There are 7 Advanced Programming options. The following Table Identifies each option and when it is used.
Advanced
Model
Option
A1
Max
A2
Max
A3
Max
A4
Max
A5
Max
A6
DMS
Equipped
Models
A7
Max
332305B
Setting
Format/ Description
Lockout
Secures setup modes with
Code
PIN
(Optional)
Low Level
MM:SS (minutes:seconds)
Alarm Time
sets amount of time
between Low Level Warning
to Low Level Fault.
Default = 3 minutes
Vent Valve
MM:SS (minutes:seconds)
Time
sets amount of time vent
valve stays open after Pump
ON Mode.
Default = 5 minutes
Alarm Retry Sets number of automatic
retries after a Cycle or Pres-
sure Alarm.
Default = 0
Active
Changes alarm output
Alarm
behavior.
Default = OFF
Functional
Clears the Functional and
and Techni-
Technical User Summaries
cal User
Summary
Reset
Constant
Changes alarm output
Alarm Out-
behavior.
put on Fault
Default = OFF
Advanced Programming
Why Use This?
Prevents unauthorized users to adjusting
settings.
To accommodate most lubrication situa-
tions, a conservative amount of time is pro-
grammed between the low level warning
and fault to help protect unit from running
dry. If necessary the amount of time the
unit runs before stopping due to a low level
fault can be adjusted.
• In an injector based system that does not
use a sensor for feedback, determines
the amount of time the system vents.
• Vent time can be modified.
Establishes the number of times the unit
automatically retries lubricating after a
cycle or pressure alarm to determine if a
temporary or false signal can be cleared.
Uses alarm output to determine if a unit has
an alarm AND/OR loses power.
The output turns ON when power is
applied. It turns OFF when power is lost or
an alarm occurs.
Normal operation (OFF) will only activate
alarm output in an alarm condition when
power is on.
Can change (set to ON) to activate alarm
with power ON and deactivate with power
OFF OR warning.
Used to manage power outage.
Allows user to track lube events from a spe-
cific point (reset), i.e. a month to month
evaluation.
This function changes the behavior of the
alarm output in a fault from either toggling
once every second or steady on.
45