A10 - Low Level Reset Upon Power On.
This function changes the behavior of the low level upon
pump power on. When A10 is on, a low level fault clears when
the pump power is cycled. The pump will revolve 5
revolutions, checking to see if the low level condition is still
present. If not, it will self clear and continue. If a low level
condition exists during the 5 revolutions, it will go into a low
level fault.
Low Level ON LED illuminates (F
F
. 30
IG
1.
The default OFF is displayed.
The alarm output will toggle
once a second.
2.
Press the UP or DOWN
ARROW button to change OFF
to ON on the display to change
the low level reset upon power
on.
332298M
. 30).
IG
3.
Press the ENTER button.
A11- Warning Off Through Alarm Relay
This function changes the behavior of the alarm output in a
warning condition to always off.
Fault and Warning LEDs Illuminate
F
. 31
IG
1.
The default OFF is
displayed. The alarm
output will turn on
during a warning
condition.
2.
Press the UP or DOWN ARROW
to change OFF to ON on the
display to change the alarm
output to be off during a
warning condition.
3.
Press the ENTER button to exit Advanced
Programming.
Advanced Programming