Advertisement

Advanced Programming

Advanced Programming
There are several Advanced Programming options. The following Table identifies each option and when it is used.
Advanced
Setting
Option
A1
Lockout
Code (Optional)
A2
Low Level Alarm
Time
A5
Active Alarm
A7
Constant Alarm
Output on Fault
Firmware 6.02 and later
A8
4 Digit Hour Off
Time
Firmware 6.04 and later for non-DMS models and 07.07 and later for DMS models
A10
Low Level Reset
Upon power ON
A11
Warning OFF
through alarm
relay
Firmware 6.06 and later for non-DMS models and 07.09 and later for DMS models
A12
Prelube
Sequences
A13
MM:SS Off Time
30
Format/ Description
Secures setup modes with
PIN
MM:SS (minutes:seconds)
sets amount of time
between Low Level Warning
to Low Level Fault.
Default = 3 minutes
Changes alarm output
behavior.
Default = OFF
Changes alarm output
behavior.
Default = OFF
Changes maximum OFF
time.
Default = OFF
Changes low level fault
upon power ON.
Default = OFF
Changes alarm output
behavior.
Default = OFF
Changes the number of the
Prelube sequences.
Changes the OFF time pro-
gramming from HH:MM to
MM:SS
Default = OFF
Why Use This?
Prevents unauthorized users to adjusting settings.
To accommodate most lubrication situations, a con-
servative amount of time is programmed between
the low level warning and fault to help protect unit
from running dry. If necessary the amount of time
the unit runs before stopping due to a low level fault
can be adjusted.
Uses alarm output to determine if a unit has an
alarm AND/OR loses power.
The output turns ON when power is applied. It turns
OFF when power is lost or an alarm occurs.
Normal operation (OFF) will only activate alarm out-
put in an alarm condition when power is on.
Can change (set to ON) to activate alarm with power
ON and deactivate with power OFF OR warning.
Used to manage power outage.
This function changes the behavior of the alarm out-
put in a fault from either toggling once every second
or steady on.
This function changes OFF time from HH:MM to
HHHH. It allows a maximum of 9999 hours of OFF
time.
This function changes the behavior of the low level
fault upon power ON.
This function changes the behavior of the alarm out-
put in a warning condition to always OFF.
This function changes the behavior of the prelube
function to add more lubrication sequences upon
pump start up.
This function changes the programming of the OFF
time.