Models With Firmware 5.06 And Later - Graco G3 Pro Instructions Manual

Automatic lubrication pump
Hide thumbs Also See for G3 Pro:
Table of Contents

Advertisement

Advanced Programming
Models with Firmware 5.06 and
later.
A12 - Prelube Sequences
This function changes the behavior of the prelube function to
add more lubrication sequences upon pump start up. While
running multiple sequences, after the initial sequence, PL:xx
will be displayed showing how many sequences are left.
Note: if pump has option "08" and using a pressure switch
with multiple sequences, a vent delay time must be
programmed under Advanced Programming Option A3.
Prelube LED illuminates (F
IG
F
. 32
IG
1.
The default 0001 is displayed.
When Prelube is on, it will run one
sequence.
2.
Press the UP or DOWN ARROW
button until desired
number of prelube
sequences displays.
NOTE: When prelube is on, and the pump is
powered-up, the pump will run this amount of lubrication
ON sequences.
36
. 30)
3.
Press the ENTER button to exit Advanced
Programming after the last digit of the
prelube sequence is displayed.
A13- MM:SS OFF Time
This function changes the programming of the OFF Time.
OFF and Warning LEDs Illuminate
F
. 33
IG
1.
The default OFF is
displayed. OFF/Backup
time in setup mode is
displayed in HH:MM
(Hours/Minutes).
2.
Press the UP or DOWN ARROW
to change OFF to ON on the
display. The OFF/Backup Time
in setup mode will be displayed
in MM:SS (Minutes/Seconds).
3.
Press the ENTER button to exit Advanced
Programming.
332298M

Advertisement

Table of Contents
loading

This manual is also suitable for:

96g01196g01296g01396g01496g02796g028 ... Show all

Table of Contents