Latched/Special-Latched Tap Start (P9); Single Or Dual Operation" (P10) Setting; Latched Special Tapping Time Setting (P11) - EWM Control HP-XQ Operating Instructions Manual

Table of Contents

Advertisement

Functional characteristics
Special parameters (advanced settings)
The number of programs (P
1st cycle
Press and hold torch trigger.
Shielding gas is expelled (gas pre-flows).
Wire feed motor runs at "creep speed".
Arc ignites after the wire electrode makes contact with the workpiece, welding current is flowing (start
program P
START
2nd cycle
Release torch trigger.
Slope to main program P
The slope to main program P
latest when the torch trigger is released. Tapping (pressing briefly and releasing within 0.3 sec)
can switch to other programs. Programs P
3rd cycle
Press and hold torch trigger.
Slope to end program P
trigger longer than 0.3 sec. P
4th cycle
Release torch trigger.
WF motor stops.
Arc is extinguished after the pre-selected wire burn-back time elapses.
Gas post-flow time elapses.
Special latched (n-cycle sequence from any program)
The function specification is the same as for n-cycle active (parameter setting 2) with the difference that
after Pstart, the program selected before the welding start follows and not P
combined with P17.

5.10.1.8 Latched/special-latched tap start (P9)

In latched – tap start – operating mode it is possible to switch straight to the second step by tapping the
torch trigger; it is not necessary for current to be flowing.
The welding can be halted by pressing the torch trigger for a second time.

5.10.1.9 "Single or dual operation" (P10) setting

If the system is fitted with two wire feeds, no further accessory components may be operated on
the 7-pole connection socket (digital)! This relates to digital remote controls, robot interfaces,
documentation interfaces, welding torches with digital control lead connection, etc.
No second wire feed may be connected in single operation (P10 = 0)!
Remove connections to the second wire feed
In dual operation (P10 = 1 or 2), both wire feed units must be connected and configured differently
on the controls for this operating mode!
Configure one wire feed unit as the master (P10 = 1)
Configure the other wire feed unit as a slave (P10 = 2)
Wire feed units with key switches (optional, > see 5.8 chapter) must be configured as masters
(P10 = 1).
The wire feed configured as the master is active after the welding machine is switched on. There
are no other functional differences between the wire feeds.

5.10.1.10 Latched special tapping time setting (P11)

The tapping time for changing over between the main program and reduced main program can be set in
three levels.
0 = no tapping
1 = 320ms (factory setting)
2 = 640ms
70
) corresponds to the cycle number specified under N cycle.
An
from P
)
A1
.
A1
is given at the earliest after the set time t
A1
from P
. The program can be stopped at any time by pressing the torch
END
AN
from P
END
AN
to P
are possible.
A1
A9
is then executed.
elapses and at the
START
. This setting can also be
A1
099-00HPXQ-EW501
07.05.2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Control HP-XQ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

M3.7x-i

Table of Contents