Programme Limit; Programs (P A 1-15) - EWM Control HP-XQ Operating Instructions Manual

Table of Contents

Advertisement

Functional characteristics
MIG/MAG welding

5.4.11 Programme limit

The JOB-dependent program limit allows you to limit the number of programs that can be selected in the
selected JOB to (2...9). This option can be set individually per JOB. In addition, a legacy option to set a
"global program limit" is also available. To set this option use special parameter P4. This setting is then
applied to all JOBs for which no JOB-dependent program limit has been set (see the special parameters
description).
You can also use the "Special latched (n-cycle)" operating mode if special parameter 8 is set to 2. In this
case (JOB-dependent program switching activated, special parameter 8 = 2, special latched) you can
switch to the next program by tapping the torch trigger in the main program (see the special parameters
description).
5.4.12 Programs (P
In the manual program P0, the user can adjust the operating point in a conventional way using the para-
meter settings on the machine control. The active program is shown in the main menu of the machine
display in the display area for process parameters with the letter "P" and the corresponding program num-
ber.
Different welding tasks or positions on a workpiece require different welding power values (operating
points) or parameter settings. These settings can be stored in up to 15 programs (P1 to P15) and recal-
led, as needed, at the machine control or a suitable accessory component (e.g. welding torch).
Welding parameters for program 0 (P0) are changed for decompact machine systems at the machine
control of the wire feeder (factory setting). To change the parameters using the Expert 2.0 machine con-
trol, the parameter "P0 changeable by Expert 2.0" must be set to "Yes".
Welding parameters for programs 1 - 15 can be changed on any control connected in the system.
The following parameters and their values are stored in each program:
Wire feed speed and voltage correction (welding power)
Operating mode, welding type, dynamics and setting superPuls
Changes to the parameter settings are stored in the selected program without further prompt.