Functional characteristics
MIG/MAG welding
5.4.9

Expert menu (MIG/MAG)

The Expert menu has adjustable parameters stored that don't require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
Display
32
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
Setting/selection
Burn-back time > see 5.4.10 chapter
• ----------- Increase value > increase wire burn-back
• ----------- Decrease value > decrease wire burn-back
Setting JOB-dependent program limit/n-cycle > see 5.4.11 chapter
1 ---------- No JOB-dependent program limit
2–9 ------- JOB-dependent program limit for max. selectable programs.
Change welding process (process switching)
With this function activated the welding process switches from standard arc welding to
pulse arc welding. Switching is effected by either tapping the torch trigger (special
latched) or by activating the superPuls function (switch between program P
------- Function activated.
------- Function deactivated.
A
B
A
Figure 5-14
and P
).
A
B
099-00HPXQ-EW501