Altronix Trove Kisi kits are pre-assembled and consists of Trove1LU1 or Trove2LU2 enclosure/backplane with factory installed Altronix power
supply/charger and sub-assemblies. Trove Kisi kits also accommodates up to four (4) Kisi Pro Controllers for up to sixteen (16) doors in a single
enclosure.
Power
Power
Supply
Supply
Board
Board
Altronix
Input
Battery
Model
Fuse
Fuse
Number
Rating
Rating
T1KE34D
5A/
10A/
T1KE38D
250V
32V
T2KE3316D
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having juris-
diction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners
and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two/three upper
screws, level and secure. Mark the position of the lower two/three holes. Remove the enclosure. Drill the lower holes and
install the two/three fasteners. Place the enclosure's upper keyholes over the two/three upper screws. Install the two/three lower
screws and make sure to tighten all screws refer to pages 6-7.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge
of the enclosure, approximately 2" from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the
appropriate UL Listed reporting device. To activate alarm signal
open the door of the enclosure.
4. Mount Kisi Pro Controllers to TLU1 or TLU2 backplane, refer to pages 3-5.
5. Refer to the ULXB Power Supply/Charger Installation Guide for AL600ULXB
and corresponding Sub-Assembly Installation Guides for ACM4CB/ACM8CB for
further installation instructions.
- 2 -
Overview:

Configuration Chart:

Maximum Supply
115VAC
Current for Main Output on
60Hz
Power Supply board
Input
and ACM4CB/ACM8CB
Current
Access Power Controllers'
(A)
outputs
3.5
24VDC @ 6A

Installation Instructions:

Nominal DC
Output Voltage
[DC]
[Aux]
Output
Output
Fail-Safe/
Range
Range
Fail-Secure
(VDC)
(VDC)
Outputs
4
20.17-
20.28-
8
26.4
26.4
16
Tamper Switch
ACM4CB/
ACM4CB/
ACM8CB
ACM8CB
Board
Board
Input
Output
Fuse
PTC
Rating
Rating
10A/
2A
250V
Enclosure
Edge of
Enclosure
(included)
To Access Control Panel or
UL Listed Reporting Device
T1KE34D/38D / T2KE3316D Installation Guide