Altronix Trove CDVI kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and
sub-assemblies. These kits also accommodate various combinations of CDVI Atrium A22K/A22NB/ADH10 boards for up to twenty (20) doors
in a single enclosure.
Altronix
Model Number
T1CVK3F4
3.5
5A/250V
T1CVK3F4D
3.5
5A/250V
T2CVK7F10
4.5
6.3A/250V
T2CVK7F10D
4.5
6.3A/250V
T2CVK33F10
7.0
5A/250V
T2CVK33F10Q
7.0
5A/250V
Networked Kit
T3CVK77F20
9.0
6.3A/250V
T3CVK77F20D
9.0
6.3A/250V
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
If your application requires a raised backplane, re-mount it using metal spacers and screws (provided).
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure.
Install two/three upper fasteners and screws in the wall with the screw heads protruding.
Place the enclosure's upper keyholes over the two/three upper screws; level and secure.
Mark the position of the lower two/three holes. Remove the enclosure. Drill the lower holes
and install the fasteners. Place the enclosure's upper keyholes over the upper screws.
Install the lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch(es) (Altronix Model TS112 or equivalent) in desired
location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure
approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access
Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open
the door of the enclosure.
4. Mount CDVI A22K/A22NB/ADH10 boards to backplane, refer to pages 3-6.
5. Refer to the eFlow Power Supply/Charger Installation Guide (eFlow6NB, eFlow104NB) and corresponding
Sub-Assembly Installation Guide (LINQ2, ACM4(CB), ACM8(CB), PD8UL(CB), MOM5) for
further installation instructions.
- 2 -
Overview:

Configuration Chart:

Maximum Supply
Current for Main and
Aux. Outputs on
Power Supply board,
MOM5 power
distribution module
or ACM4(CB)/ACM8(CB)
Access Power
Controllers' outputs
15A/
24VDC @ 5.7A
32V
15A/
24VDC @ 5.7A
32V
15A/
24VDC @ 9.4A
32V
15A/
24VDC @ 9.4A
32V
24VDC @ 5.9A
15A/
+
32V
24VDC @ 5.9A
24VDC @ 5.9A
15A/
+
32V
24VDC @ 5.9A
24VDC @ 9.4A
15A/
+
32V
24VDC @ 9.7A
24VDC @ 9.4A
15A/
+
32V
24VDC @ 9.7A

Installation Instructions:

Nominal DC
Output Voltage
Power Supply
[DC]
[Aux]
Output
Output
Range
Range
(VDC)
(VDC)
20.17-
20.28-
4
26.4
26.4
20.17-
20.28-
4
26.4
26.4
20.17-
20.28-
12
8
26.4
26.4
20.17-
20.28-
12
8
26.4
26.4
20.17-
20.28-
10
26.4
26.4
20.17-
20.28-
10
26.4
26.4
20.17-
20.28-
26.4
26.4
20
8
20.17-
20.28-
26.4
26.4
20.17-
20.28-
26.4
26.4
20
8
20.17-
20.28-
26.4
26.4
10A/
3A/
250V
32V
10A/
2.5A
250V
10A/
3.5A/
10A/
3.5A/
3.5A/
250V
250V
250V
250V
250V
10A/
10A/
2.5A
2.5A 2.5A
250V
250V
10A/
3A/
2.5A/
2.5A/
3.5A/
250V
32V
250V
250V
250V
10A/
10A/
3.5A/
2.5A
2.5A
250V
250V
250V
Enclosure
Edge of
Enclosure
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Trove CDVI Kits Installation Guide
2.5A
2.5A
Fig. 1