Setting the Conditions of Communications with the PLC by Using the Memory Switches
3-7-2

Selecting the Host Link Communication Speed

Note
74
When the host link is used, the baud rate of the communications with the PLC
can be set. Use the "Baud Rate" switch and select 9,600 bps or 19,200 bps.
The factory setting has been made at 9,600 bps.
Select the baud rate of the communication with the PLC by the menu opera-
tion from the System Menu as mentioned below.
[System Menu]
Quit
Transmit Mode
Maintenance Mode
PT Setting
I/O Check
Initialize Memory
Memory Switch
[Memory SW1]
Backlight
OFF: 10min
Auto-restart:
History Data:
[Memory SW2]
Com. Type: Host Link
Baud
Rate: 9600BPS
Com. Port: RS-232C
To quit after setting the selection made, press the "ENTER" key. To quit with-
out setting the selection made, press any two function keys simultaneously.
If the NT link has been selected, the Baud Rate setting does not make any
effect.
Select "Maintenance Mode"
1.0
with the
"ENTER".
Select "Memory Switch" with
the
"ENTER".
Display the next screen by
Page:
pressing the
Yes
Erase
Select "Baud Rate" with the
Page:
key.
Pressing the [+/–] key while
"Baud Rate" is highlighted
will cause the selection for
this item to switch as fol-
lows: 9,600 bps,
19,200 bps, 38,400 bps,
57,600 bps, and
115,200 bps.
Section 3-7
key, then press
key, then press
key.