Panasonic PT-SMZ16KCL Operating Instructions (Functional Manual) page 7

Table of Contents

Advertisement

r Hazard distance (IEC 62471-5:2015)
The distance from the projection lens surface, at which the level of exposure has reached the level of the
applicable Exposure Limit Value, is known as the hazard distance (HD) or safety distance.
Do not look into the projected light from inside the hazard distance (within RG3 range). The eyes may be damaged
by the direct irradiation. It is considered to be safe to look into the projected light from outside the hazard distance
(within RG2 range).
D1
RG2
D2
r Risk group
The combination of the projector and the projection lens is categorized as the risk group 2 when the hazard
distance is less than 1 m (39-3/8
(39-3/8
), and it will be for professional use instead of consumer use.
"
In case of risk group 3, there is a possibility of damaging the eyes by direct irradiation when looking into the
projection light from inside the hazard distance (within RG3 range).
In case of risk group 2, it can be used safely without damaging the eyes in any condition.
The combination of the projector and the projection lens which the hazard distance exceeds 1 m (39-3/8") and is
categorized as risk group 3 is as follows.
Model No.
PT-SMZ16KCL
PT-SMZ13KCL
PT-SMZ10KCL
*3
*1 The risk group varies depending on the throw ratio of the actual use condition.
*2 When PT-SMZ16KCL or PT-SMZ13KCL is used with the optional Zoom Lens (Model No.: ET-EMT800) attached, the hazard
distance exceeds 1 m (39-3/8") and therefore it is categorized as the risk group 3.
*3 When PT-SMZ10KCL is used with the optional Zoom Lens (Model No.: ET-EMT700) attached, the hazard distance is less than
1 m (39-3/8") and therefore it is categorized as the risk group 2.
Read this first!
HD
RG3
). It is categorized as the risk group 3 when the hazard distance exceeds 1 m
"
Projection lens Model No.
ET-EMT700
*1
ET-EMT800
*2
ET-EMT700
*1
ET-EMT800
*2
ET-EMT800
*1
D3
RG2
RG3
D4
Use condition
When the throw ratio is 2.9:1 or less
When the throw ratio exceeds 2.9:1
When the throw ratio is 3.4:1 or less
When the throw ratio exceeds 3.4:1
When the throw ratio is 4.6:1 or less
When the throw ratio exceeds 4.6:1
HD
Risk group
Risk group 2
Risk group 3
Risk group 3
Risk group 2
Risk group 3
Risk group 3
Risk group 2
Risk group 3
ENGLISH - 7