10) After the name is input, press asqw to select [OK], and press the <执行> button.
f Saving of the lens memory is completed, and returns to the [LENS MEMORY SAVE] screen.
f If you press asqw to select [CANCEL] and then press the <执行> button, the lens memory will not be
saved.
f If you press asqw to select [DEFAULT] and press the <执行> button, the entered name will not be
registered and the default name will be used.
f If you select [OK] without entering any characters and press the <执行> button, the default name will be
used.
Note
f The numeric value information of the periphery focus position is displayed only when one of the following lenses is attached.
g ET-EMW200, ET-EMW300, ET-EMW400, ET-EMW500
Loading the lens position
1)
Press as to select [LENS].
2)
Press the <执行> button.
f The [LENS] screen is displayed.
3)
Press as to select [LENS MEMORY].
4)
Press the <执行> button.
f The [LENS MEMORY] screen is displayed.
5)
Press as to select [LENS MEMORY LOAD].
6)
Press the <执行> button.
f The [LENS MEMORY LOAD] screen is displayed.
f The name of the saved lens memory and its lens position information ([VERTICAL POSITION]/
[HORIZONTAL POSITION]/[FOCUS POSITION]/[ZOOM POSITION]/[PERIPHERY FOCUS POSITION])
are displayed in the [LENS MEMORY LOAD] screen.
7)
Press as to select the item to load, and press the <执行> button.
f The confirmation screen is displayed.
8)
Press qw to select [OK], and press the <执行> button.
f The lens will automatically move to the lens position (vertical position, horizontal position, focus position,
zoom position, and periphery focus position) of the loaded lens memory.
Note
f Lens memory is not guaranteed to be 100 % reproduced. Readjust the focus, periphery focus, zoom, and lens shift after loading the lens
memory if required.
f If the projection lens is replaced, execute the [PROJECTOR SETUP] menu → [LENS] → [LENS CALIBRATION], readjust the focus,
periphery focus, zoom, and lens shift, and save the lens memory again.
f Lens memory with numeric value information of the periphery focus position displayed is the lens memory saved when one of the following
lenses is attached.
g ET-EMW200, ET-EMW300, ET-EMW400, ET-EMW500
f If the lens position is loaded while the [PROJECTOR SETUP] menu → [LENS] → [ACTIVE FOCUS OPTIMIZER] → [ACTIVE FOCUS] is set
to [ON], the operation of the temperature detection correction of the active focus optimizer function will stop.
f The saved lens memory is loaded in order every time the <功能> button is pressed when [LENS MEMORY LOAD] is assigned to the <功能
> button.
Deleting a lens memory
1)
Press as to select [LENS].
2)
Press the <执行> button.
f The [LENS] screen is displayed.
3)
Press as to select [LENS MEMORY].
4)
Press the <执行> button.
f The [LENS MEMORY] screen is displayed.
Chapter 4 Settings — [PROJECTOR SETUP] menu