Adjusting The Focus Balance - Panasonic PT-SMZ16KCL Operating Instructions (Functional Manual)

Table of Contents

Advertisement

Note
f The focus adjustment and the zoom adjustment cannot be performed in following case.
g When [---] is displayed in the [PROJECTOR SETUP] menu → [LENS] → [LENS TYPE]
f The adjustment can be performed faster by holding down asqw while adjusting the focus or zoom.
f The adjustment can be performed faster by holding down asqw for approximately three seconds or longer while adjusting the lens shift.
f When the [PROJECTOR SETUP] menu → [LENS] → [ACTIVE FOCUS OPTIMIZER] → [ACTIVE FOCUS] is set to [OFF], it is
recommended to perform the focus adjustment after 30 minutes or more have elapsed with the focus test pattern displayed.
For details of [ACTIVE FOCUS OPTIMIZER], refer to the [PROJECTOR SETUP] menu → [LENS] → [ACTIVE FOCUS OPTIMIZER]
(x page 124).
For details of the test pattern, refer to "[TEST PATTERN] menu" (x page 146).
f Only [FOCUS] is displayed in yellow so that the displayed menu item can be recognized by color, even when the displayed characters are
unreadable due to incorrect focus. (Factory default)
The displayed color of [FOCUS] differs depending on the setting of the [DISPLAY OPTION] menu → [ON-SCREEN DISPLAY] → [OSD
DESIGN].
f If the focus adjustment, periphery focus adjustment, or zoom adjustment is executed while the [PROJECTOR SETUP] menu → [LENS] →
[ACTIVE FOCUS OPTIMIZER] → [ACTIVE FOCUS] is set to [ON], the operation of the temperature detection correction of the active focus
optimizer function will stop.
f When the projector is switched off during the lens shift adjustment, lens calibration needs to be performed the next time the projector is
switched on. (x page 123)
f When the main power is switched off during the lens shift adjustment, the lens calibration error screen is displayed during the next lens shift
adjustment. Execute the [PROJECTOR SETUP] menu → [LENS] → [LENS CALIBRATION].
f When the lens calibration error is displayed even though [LENS CALIBRATION] was executed, ask your dealer to repair the unit.

Adjusting the focus balance

By changing the projected image size, the focus balance in the center and periphery of the image may be lost.
f Focus, zoom, and periphery focus cannot be adjusted by turning the projection lens by hand.
f Adjust the focus balance in the center and periphery of the projected image with the periphery focus when
following projection lens is used.
g Zoom Lens (Model No.: ET-EMW200, ET-EMW300, ET-EMW400, ET-EMW500)
f The steps are an example when attaching the Zoom Lens (Model No.: ET-EMW200).
1)
Adjust the focus at the center of projected image.
f For the steps to adjust the focus, refer to "Adjusting the focus, zoom, and lens shift" (x page 63).
2)
Press the <执行> button.
f The [PERIPHERY FOCUS] adjustment screen is displayed.
3)
Press asqw to adjust.
4)
Press the <执行> button again.
f The [FOCUS] adjustment screen is displayed.
5)
Press asqw to adjust the focus at the center of the image.
f Check the focus at the center and periphery of the image and and make fine adjustments.
f The projected image size may change when the focus in the periphery of the image is adjusted.
Check the projected image size too when adjusting the focus balance in the center and periphery of the
image.
Note
f When the projector is used for the first time or when the projection lens is replaced, confirm that the display of the [PROJECTOR SETUP]
menu → [LENS] → [LENS TYPE] is appropriate, and then execute the [PROJECTOR SETUP] menu → [LENS] → [LENS CALIBRATION].
f If the periphery focus adjustment is executed while the [PROJECTOR SETUP] menu → [LENS] → [ACTIVE FOCUS OPTIMIZER] →
[ACTIVE FOCUS] is set to [ON], the operation of the temperature detection correction of the active focus optimizer function will stop.