kozy heat KPV Manual
Hide thumbs Also See for KPV:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

KOZY POWER VENT
#KPV
Kozy Power Vent Approved Fireplaces:
#CLW-72
READ ALL THESE STEPS
BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE
APPLIANCE.
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of
the heater installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the appliance.
Please read the appliance owner's manual
completely before performing any procedures in
these instructions.
1.0 INTRODUCTION .......................................................................3
1.1 Introduction ......................................................................................... 3
1.2 Components and Service Parts List ............................................. 3
1.3 Installation ............................................................................................ 3
2.0 VENTING ...................................................................................4
2.1 Venting Requirements ..................................................................... 4
2.2 Horizontal Terminations .................................................................. 5
2.3 Draft Bypass Adjustment ............................................................... 7
3.0 FRAMING AND CLEARANCES ................................................8
3.1 Framing and Clearances .................................................................. 8
3.2 Clearances to Combustibles .......................................................... 9
3.3 Rooftop Termination ......................................................................... 9
3.4 Termination Cap Clearances ........................................................10
3.5 Installing Vent Cap ...........................................................................11
4.0 ELECTRICAL INFORMATION ................................................15
4.1 Wiring to the Appliance .................................................................15
5.0 MAINTENANCE .....................................................................19
5.1 Replace Fan Assembly/Vacuum Switch ...................................19
6.0 TROUBLESHOOTING .............................................................21
P.O. Box 577, 204 Industrial Park Drive
Lakefield, MN 56150-0577, USA
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
HUSSONG MANUFACTURING CO., INC.
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez www.kozyheat.com .
IMPORTANT: Failure to read and follow these
instructions may create a possible hazard and
will void the fireplace warranty.
Kozy Power Vent #KPV
Rev. 1, 4/19

Advertisement

Table of Contents
loading

Summary of Contents for kozy heat KPV

  • Page 1: Table Of Contents

    5.0 MAINTENANCE ..............19 will void the fireplace warranty. 5.1 Replace Fan Assembly/Vacuum Switch ........19 6.0 TROUBLESHOOTING .............21 Hussong Manufacturing Co., Inc. P.O. Box 577, 204 Industrial Park Drive Kozy Power Vent #KPV Lakefield, MN 56150-0577, USA Rev. 1, 4/19...
  • Page 3: Introduction

    This is to allow a pre-ignition purge by the will result in conditions which may produce bodily injury and/or #KPV. If after 135 seconds the pilot and burner do not light, refer to property damage. Section 6.0 on page 21 of this manual. There will be also 120 second post-operation purge in which #KPV will continue to run after the 1.3.2 Installation Guidelines...
  • Page 4: Venting

    • The #KPV is for use 4" x 6-5/8" coaxial rigid direct vent pipe. A 5" x 8" to a 4" x 6-5/8" vent reducer for DuraVent and Selkirk vent systems must be used. See appliance installation manual for approved venting.
  • Page 5: Horizontal Terminations

    Use Table 2.1 for venting guidelines. Figures 2.2 and 2.3 provide a guide to calculate total vent run. • No vertical rise is required with #KPV. The venting can run horizontal directly off the appliance. Table 2.1, KPV Venting Guidelines...
  • Page 6 Figure 2.5, Horizontal Termination Guide 2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent #KPV...
  • Page 7: Draft Bypass Adjustment

    * This draft setting is allowed on all vent configurations except a vent configuration with a vertical drop Figure 2.7, Adjust the Draft Bypass Figure 2.8, Shown in Position 3 Kozy Power Vent #KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 8: Framing And Clearances

    3.0 FRAMING AND CLEARANCES 3.1 Framing and Clearances IMPORTANT: Framework for #KPV MUST be level to ensure precipitation does not build up inside the power vent unit. Chassis dimensions are shown in Figure 3.1. 3.1.1 Framing Dimensions Construct a framework as shown in Figure 3.2. Framework material should be the same dimensions as the material used for the wall framing.
  • Page 9: Clearances To Combustibles

    TOP VIEW SIDE VIEW Figure 3.3, Minimum Clearances to Combustibles 3.3 Rooftop Termination If the #KPV is going to terminate on a flat roof, an enclosure similar to the one shown in Figure 3.4 needs to be constructed. ½ 1”...
  • Page 10: Termination Cap Clearances

    VINYL SOFFIT, VINYL CEILING, AND VINYL OVERHANG DISCLAIMER: Clearances to heat resistant material (i.e. wood, metal). This does not include vinyl. Hussong Manufacturing Co., Inc. will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings, or vinyl ventilated/unventi- lated soffits. Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent #KPV...
  • Page 11: Installing Vent Cap

    Slide the exhaust assembly out of the back of the cap. See Figure 3.7 and Figure 3.8. Remove the two corrugated shipping pads. See Figure 3.9. Install #KPV wiring harness through the electrical access hole in the back cover cap. See Figure 3.10. Instructions continue on the next page.
  • Page 12 Attach the red and brown wires to the vacuum switch as shown in Figure 3.12. Attach the white and black wires from the #KPV harness to the black wires coming from the blower. Attach the green wire from the #KPV harness to the green/yellow wire coming from the fab.
  • Page 13 1" thick. Order with the appliance and venting system. It will be used to ensure that the finishing is done to appropriate size for the #KPV-FEK to be installed properly. IMPORTANT: IT IS IMPERATIVE THAT #KPV-FEK IS LEVEL TO ENSURE THE POWER VENT IS LEVEL.
  • Page 14 NOTE: Be careful not to tear the gasket on the mounting flange on the #KPV back assembly during re-assembly in Step 12. 11. Reinstall the #KPV back assembly that was removed in Step 1 of Section 3.5. 12. Once the cap is fastened to the wall, apply a bead of silicone (with a minimum of 300°F continuous exposure rating) around...
  • Page 15: Electrical Information

    See Figure 4.3. Reinstall control module top cover. Plug in all components previously unplugged. Figure 4.2, JP1 Jumper Figure 4.3, Plastic Jumper Removed Figure 4.1, Remove Control Board Cover Kozy Power Vent #KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 16 4.1.2 Wiring the KPV to the Appliance NOTE: Use Figure 4.7 and Figure 4.8 as wiring schematic references when following the individual instructions below. Find the hole in either side of the fireplace for access to Power Vent wiring. See the top picture of Figure 4.4. The power vent wire harness hole is located on a removable plate.
  • Page 17 GREEN BLACK WHITE BROWN Figure 4.7, Power Vent Internal Wiring Kozy Power Vent #KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 18 BROWN VACUUM SWITCH WHITE BLACK GREEN Figure 4.8, Fireplace Internal Wiring Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent #KPV...
  • Page 19: Maintenance

    After replacing the components, reinstall all the previously removed components in reverse order. Figure 5.3, Exhaust Assembly Removal Figure 5.1, Front Cover Assembly Removal Figure 5.4, Remove Hot, Neutral and Ground wire Kozy Power Vent #KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 20 Figure 5.5, Remove Vacuum Tube Figure 5.8, Screws Securing Vacuum Switch Bracket Figure 5.6, Remove (3) Screws Securing Fan Assembly Figure 5.9, Vacuum Switch Removal Figure 5.7, Fan Assembly Removal Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent #KPV...
  • Page 21: Troubleshooting

    Check vacuum tube for a solid connection between the vacuum switch and the vacuum port of the fan assembly Check for faulty or incorrect wiring between the vacuum switch and control module Replace vacuum switch Kozy Power Vent #KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 22 Reprogram remote control to IFC module. See appliance installation remote control and IFC module manual. A maximum number of failed Reset IFC module. See appliance installation manual. ignitions or flame restorations has been reached Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent #KPV...
  • Page 24: Hussong Manufacturing Co., Inc

    5.1 Remplacement du ventilateur et du interrupteur d’aspiration ...19 ger et annulera la garantie du foyer. 6.0 DÉPANNAGE ................21 Hussong Manufacturing Co., Inc. P.O. Box 577, 204 Industrial Park Drive Kozy Power Vent nº KPV Lakefield, MN 56150-0577, USA Rev. 1, 4/19...
  • Page 26: Introduction

    Ceci afin de permettre une du système Power Vent non conforme aux instructions du purge de pré-allumage par le KPV. Si après 135 secondes, la veilleuse et fabricant causera des conditions pouvant entraîner des blessures le brûleur ne s’allument pas, voir la Section 6.0 (page 21) de ce manuel.
  • Page 27: Conduit D'évacuation

    • Le KPV est conçu pour utiliser du conduit d’évacuation directe rigide coaxial 4 po x 6-5/8 po. Un réducteur d’évacuation de 5 x 8po à 4 x 6-5/8po doit être utilisé pour les systèmes de cheminée DuraVent et Selkirk.
  • Page 28: Terminaisons Horizontales

    Utilisez les directives d’évacuation du Tableau 2.1. Les Figures 2.2 et 2.3 servent de guide pour calculer le trajet d’évacuation total. • Aucune élévation verticale n’est requise avec le KPV. Le conduit d’évacuation peut sortir horizontalement directement de l’appareil. Tableau 2.1, Directives d’évacuation du KPV...
  • Page 29 Figure 2.5, Conduit d’évacuation horizontal - Guide 2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent nº KPV...
  • Page 30: Draft Bypass Adjustment

    * Ce réglage de tirage est permis pour toutes les configurations d’évacuation, sauf pour celles qui ont une chute verticale Figure 2.7, Ajustement de la dérivation de tirage Figure 2.8, Ajustement montré en Position 3 Kozy Power Vent nº KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 31: Encadrement Et Dégagements

    3.0 ENCADREMENT ET DÉGAGEMENTS 3.1 Encadrement et dégagements IMPORTANT: L’encadrement du KPV DOIT être de niveau pour s’assurer que l’eau de pluie ne s’accumule pas à l’intérieur du système Power Les dimensions d'encadrement sont montrées à la Figure 3.1. Vent.
  • Page 32: Dégagements Aux Matériaux Combustible

    VUE DU DESSUS VUE DU CÔTÉ Figure 3.3, Dégagements minimums aux matériaux combustibles 3.3 Terminaison au toit Si le KPV doit se terminer sur un toit plat, une enceinte similaire à celle montrée à la Figure 3.4 devra être construite. ½ 1”...
  • Page 33: Dégagements Du Chapeau D'évacuation

    Ceci n'inclut pas le vinyle. Hussong Manufacturing Co., Inc. pas responsable des dommages dus à la chaleur si la terminaison (conduit) d'évacuation aboutit sous un avant-toit (ex. corniche) en vinyle, un plafond en vinyle ou un soffite (ventilé ou non ventilé) en vinyle Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent nº KPV...
  • Page 34: Installation Du Chapeau D'évacuation

    Figure 3.7 et Figure 3.8. Retirez les deux cartons d’expédition cannelés. Voir Figure 3.9. Insérez le faisceau de câble du KPV dans le trou d’accès électrique dans le couvercle arrière du chapeau. Voir Figure 3.10. (Suite des instructions à la page suivante.) Figure 3.8, Évacuateur retiré...
  • Page 35 Passez à la Section 3.5.1 Matériaux de finition (page 13). Figure 3.13, Fils connectés Figure 3.11, Mesurage des fils avec un ruban à mesurer Figure 3.12, Interrupteur d’aspiration Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent nº KPV...
  • Page 36 PowerVent (KPV). IMPORTANT: IL EST IMPORTANT QUE LE KIT D’EXTENSION KPV-FEK SOIT DE NIVEAU POUR QUE LE KIT POWER VENT (KPV) SOIT AUSSI DE NIVEAU. CECI EST NÉCESSAIRE POUR S’ASSURER QUE L’EAU DE PLUIE NE S’ACCUMULE PAS DANS LE CHAPEAU D’ÉVACUATION. Veillez à ce que l’installation du KPV-FEK affleure au mur extérieur.
  • Page 37 NOTE: Be careful not to tear the gasket on the mounting flange on the #KPV back assembly during re-assembly in Step 12. 11. Réinstallez l’assemblage arrière du KPV, que vous aviez retiré à l’étape 1 de la Section 3.5. 12. Une fois le chapeau d’évacuation fixé au mur, appliquez un joint de silicone (résistance minimale de 300°F en exposition...
  • Page 38: Installation Électrique

    Réinstallez le couvercle du module de contrôle. Branchez tous les composants débranchés précédemment. Figure 4.2, Cavalier JP1 Figure 4.1, Retrait du couvercle du panneau de contrôle Figure 4.3, Cavalier en plastique retiré Kozy Power Vent nº KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 39 Figure 4.6, Serre-fils installés aux fils identifiés «APS» Trou pour le faisceau de câble du Power Vent Figure 4.4, Câble du Power Vent fixé au foyer CLW-72 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent nº KPV...
  • Page 40 VERT NOIR BLANC ROUGE BRUN Figure 4.7, Câblage interne du Power Vent Kozy Power Vent nº KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 41 INTERRUPTEUR BRUN D’ASPIRATION ROUGE BLANC VENTILATEUR NOIR VERT Figure 4.8, Câblage interne du foyer Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent nº KPV...
  • Page 42: Entretien

    Figure 5.3, Retrait de l’évacuateur Figure 5.1, Retrait du couvercle avant Figure 5.4, Retrait des 3 fils : porteur, neutre et de terre Kozy Power Vent nº KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 43 Figure 5.8, Les vis retenant la bride de l’interrupteur d’aspiration Figure 5.6, Retrait des (3) vis de fixation du ventilateur Figure 5.9, Retrait de l’interrupteur d’aspiration Figure 5.7, Retrait du ventilateur Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent nº KPV...
  • Page 44: Dépannage

    Vérifier s’il y a un câble mal connecté ou défectueux entre l’interrupteur d’aspiration et le module de contrôle. Remplacer l’interrupteur d’aspiration. Kozy Power Vent nº KPV Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 45 Le nombre maximal d’échecs Réinitialiser le module de contrôle IFC. Voir le manuel d’installation de d’allumage ou de restauration l’appareil. de flamme est atteint Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kozy Power Vent nº KPV...