Initializing Disk Drives - Supermicro X6DLP-EG2 User Manual

Supermicro x6dlp-eg2 motherboards: user guide
Table of Contents

Advertisement

Appendix C: Software Installation Instructions

Initializing Disk Drives

If an installed disk does not appear in the disk selection list for creating a new ar-
ray, or if it appears grayed out, you may have to initialize it before you can use it
as part of an array. Drives attached to the controller must be initialized before they
can be used in an array.
Caution: Initializing a disk overwrites the partition table on the disk and makes any
data on the disk inaccessible. If the drive is used in an array, you may not be able
to use the array again.
Do not initialize a disk that is part of a boot array. To determine which disks are
associated with a particular array, please refer to
Viewing Array Properties.
To initialize drives:
1. Turn on your computer and press Ctrl+A when prompted to access the ARC
utility.
2. From the ARC menu, select Array Confi guration Utility (ACU) (as shown in the
screen below).
3. Select Initialize Drives (as shown in the screen below).
C-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

X6dlp-4g2

Table of Contents