5-7. Connecting To Weld Output Terminals

Tools Needed:
3/4 in.
6
3
4
5
Notes
.
Complete Parts List available at www.MillerWelds.com
1
2
!
Stop engine.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your ma-
chine.
.
Do not place anything between weld
cable terminal and copper bar. Make
sure that the surfaces of the weld
cable terminal and copper bar are
clean.
1
Correct Weld Cable Connection
2
Incorrect Weld Cable Connection
3
Weld Output Terminal
4
Supplied Weld Output Terminal Nut
5
Weld Cable Terminal
6
Copper Bar
Remove supplied nut from weld output
terminal. Slide weld cable terminal onto
weld output terminal and secure with nut
so that weld cable terminal is tight against
copper bar.