6-14. Optional Air Dryer Operation (Air Pak Models)

OM-279640 Page 52
.
Complete Parts List available at www.MillerWelds.com
2
1
The air dryers blow out (purge) mois-
ture and debris when the air compres-
sor is being used. The air dryer heaters
operate whenever the welder/genera-
tor is running.
See the supplied air dryer Owner's
Manual for air dryer maintenance and
service information.
.
When battery access is required,
disconnect and remove the air
dryer assembly as described in
Section 8-13.
1
Circuit Breaker CB14
CB14 protects the dryer heaters from
damage due to overload. If CB14
opens, the heaters do not work and the
dryer does not discharge moisture in
cold weather.
Press button to reset circuit breaker
CB14.
.
When a circuit breaker opens, it
usually indicates a more serious
problem exists. Contact a Factory
Authorized Service Agent.
Start engine, and turn on air compres-
sor. Check fittings for air leaks and
tighten fittings if necessary.
2
Timer Control LED
Verify dryer solenoid is functioning by
listening for dryer canisters to purge, or
by checking solenoid LED. LED lights
at start-up and every two minutes
when the canisters automatically
purge.
907 535−2 / 803 228 / 803 229