Boiler lining for GL-E burner

Boiler lining
The burner lining must be installed at a
right angle to the burner tube. Possible
trimming work (bevelling, rounding) as
required for reverse boilers, for example,
should done at a diameter not below
70% of the combustion chamber
diameter. The space between the flame
tube of the burner and the boiler lining
should be lined with heat resistant
material, such as Cerafelt.
This space must not be lined with
brickwork
N/EKEVO 6-7
N/EKEVO 8-9
8
03/2016 - Art. Nr. 4200 1044 8002A
D
= see technical data
D1
= see technical data
DF
= combustion chamber diameter
T1
= see table
N6, N7/EKEVO 6,7 GL-E
N8/EKEVO 8.5800 GL-E
N8/EKEVO8.7100 GL-E
N9/EKEVO 9.8700 GL-E
N9/EKEVO 9.10400 GL-E
T
= standard muffle depth
(option : extensions: see technical
data)
Please note for reverse flow boilers:
For reverse flow boilers, dimension T1 is
only a recommended value. Depending
on the type of boiler, the combustion
head must project at least beyond the
reversal gap by the dimension below.
N6,N7/EKEVO 6,7: 50mm
N8,N9/EKEVO 8,9: 50mm
T1
70 - 200
212 - 352
230 - 370
2 - 150