Recording Area - Sanyo DSR-5709P Instruction Manual

Digital video recorder with multiplexer function
Hide thumbs Also See for DSR-5709P:
Table of Contents

Advertisement

3
RECORD SET
AREA FULL RESET
If "OVERWRITE" is set to "OFF" for recording conditions,
recording automatically stops when the recording areas
become full. In this case, AREA FULL RESET can be used to
overwrite previous recordings.
4
Click [AREA FULL RESET] under

"RECORDING AREA".

To perform AREA FULL RESET for the archive area, click
[AREA FULL RESET] under "ARCHIVE AREA".
When AREA FULL RESET is performed for "RECORDING
AREA", the recordings in the recording area are
overwritten.
When AREA FULL RESET is performed for "ARCHIVE
AREA", the recordings in the archive area are overwritten.
2. RECORDING CONDITIONS SET
Use the following procedure to set the permission for
overwriting to recording areas or the remaining-space warning
level.
Setting overwriting permission for recording
areas
When the recording areas become full, this setting dictates
whether recording stops or continues by overwriting the
recorded images currently stored on the hard disk.
1
Click the
button on the operation
panel.
The "MAIN MENU" is displayed.
2
Click "2. RECORD SET".
The "RECORD SET" screen is displayed.
3
Click "2. RECORDING CONDITIONS
SET".
The "RECORDING CONDITIONS SET" screen is displayed.
RECORDING CONDITIONS SET
4
RECORDING AREA
OVERWRITE
ARCHIVE AREA
MODE
5
REMAINING DISK WARNING :
6
AUTO DELETE
7
SAVE
:
ON
: MANUAL COPY
1
%
:
OFF
4
Set "OVERWRITE" for the "RECORDING
AREA" to "ON" or "OFF".
[Settings] (
indicates default setting)
Setting
Recording stops when a recording area becomes
OFF
full.
When a recording area becomes full, overwriting
ON
from the beginning of this area starts
automatically.
Setting the remaining-space warning level
When the overwrite setting for a recording area is "OFF", the
unit can issue a warning as soon as the remaining space
reaches a specific level. ( P.195)
Use the following procedure to set the level at which the
warning is issued.
5
Set "REMAINING DISK WARNING" to
the desired remaining-space warning
level.
[Settings] (
indicates default setting)
Setting
Remaining-space warning level can be set from
1 - 10
1% to 10%.
Setting AUTO DELETE
Use the following procedure to set the storage period for
recorded data. When the set period expires, the
corresponding data is automatically deleted.
6
Set "AUTO DELETE" to the desired
storage period.
[Settings] (
indicates default setting)
Setting
OFF
Auto delete is disabled.
1 - 99
Set the storage period for recorded data from "1
DAYS
DAY" to "99 DAYS" (full days).
7
Click [SAVE].
The setting is saved.
188
Description
Description
Description
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsr-5716p

Table of Contents