9
ADVANCED MENU SET
2. CAMERA CONTROL SET
Set when cameras with remote operation capability are
connected.
Perform the following connections and set camera control to
use in full screen display.
Connections necessary for remote operation:
Connect coaxial control cameras to the VIDEO terminal.
Connect the Sanyo RS-485 control camera to the RS-485
terminal (RJ-11).
Connect the other companies' RS485/422 control camera
to the 2ND RS485/422 terminal.
1
Click the
button on the operation
panel.
The "MAIN MENU" is displayed.
2
Click "8. ADVANCED MENU SET".
The "ADVANCED MENU SET" screen is displayed.
3
Click "2. CAMERA CONTROL SET".
The "CAMERA CONTROL SET" screen is displayed.
The DSR-5709P displays only nine channels.
5
4
8
10
4
Set "PROTOCOL" to the protocol
corresponding to the dome camera.
[Settings] (
indicates default setting)
Setting
OFF
No protocol
SANYO RS485
SANYO RS485
BBV COAX
BBV COAX
(Also supports AUX commands.)
PELCO COAX
PELCO COAX
2ND RS-485/422
2ND RS-485/422
COAX (H-SSP)
COAX (H-SSP)
English
6
9
Description
5
The address (000 to 127) is displayed in
"ADD".
When "SANYO RS485" or "2ND RS485/422" is specified as
the protocol, the address is displayed automatically.
6
To "ACTION", specify an interlocking
behavior of camera to be exhibited
when an alarm is detected.
You can control the behavior of the camera such as alarm-
triggered lens orienting, and pan and tour movement.
[Settings] (
indicates default setting)
Setting
OFF
No action triggered.
Moves the camera lens to the angle
PRESET
corresponding to your selected preset
number.
PAN
Starts automatic panning.
TOUR
Starts tour.
SEQUENCE
Starts sequence.
For "PRESET", you can set "PRESET2-9" with DSR-5709P
and "PRESET2-16" with DSR-5716P.
Actually available actions depend on each camera. For
more information, refer to the camera's instruction manual.
7
Use the same procedure to set the other
channels.
8
Set "2ND RS-485/422 PROTOCOL".
[Settings] (
indicates default setting)
OFF, BBV, KALATEL, PELCO, SENSORMATIC
9
Set "DATA SPEED".
[Settings] (
indicates default setting)
9600bps, 4800bps, 2400bps
10
Click [SAVE].
The setting is saved.