RECORDING IMAGES IN THE
NORMAL RECORDING AREA

Normal recording

Images can be recorded in the normal recording area while they are being monitored.
Insert the power cord into a wall outlet and turn on the
1
power.
The POWER indicator illuminates, and after approximately 15 seconds, the
EXIT/OSD indicator illuminates. The camera images appear on the monitor,
POWER
and the operating display appears in the top-left corner of the screen.
Note: The operating display can be moved or switched off by pressing the
EXIT/OSD
Setting the time
2
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and
set the date and time. After the setting has been made, press the EXIT/OSD
MENU
button, the date and time appear in the operating display. (See page 40.)
Press the REC/STOP button.
3
"a" appears in the operating display and the images being monitored are
recorded in the normal recording area. Recording onto the hard disk
REC/STOP
proceeds automatically (default setting) according to the following settings.
The settings can be changed between long-period recording and high-quality
recording in five steps. (See page 47.)
Note: Playback is possible during recording. When the PLAY/STOP button is
Press and hold the REC/STOP button for 3 seconds or
4
more.
The "a" in the operating display disappears and recording stops.
REC/STOP
Note: When the remaining area in the normal recording area drops below the
EXIT/OSD button repeatedly.
See page 11 for details of the operating display.
Hard disk recording areas:
Normal recording area: 80%
Alarm recording area: 19%
Archive area: 1%
Picture quality: EN (Enhanced)
Recording method: Field
Recording speed: 0.12 seconds (65H)
pressed during recording, "c" appears in the operating display and
images are played back from the point where recording began. (See
page 19.)
set amount, the FULL indicator on the front panel flashes. If recording
continues under these conditions, the recording area becomes full and
recording stops. In the RECORDING AREA SET settings, carry out the
AREA FULL RESET operation for the normal recording area.
Recording will then be possible from the beginning again. (See page
44.)
12
Monitored images
are recorded.
Operating display
Recording start time
POWER
FULL
ALARM FULL
English
LOC