ELECTRICAL CONNECTION 
The  appliance  shall  be  connected  to a  single 
phase  electric  line  rated  at  120/208Vac  or 
120/240Vac and 60Hz frequency. 
 
Electric power rating: 
‐ 120/208Vac: 5000 Watt or 24.3 A max. 
‐ 120/240Vac: 6500 Watt or 27.8 A max. 
 
Heating elements power rating: 
‐ Oven bake element = 2400 Watt 
‐ Oven circular element = 3300 Watt 
‐ Oven broil element = 4000 Watt 
 
Install a suitable electric power supply receptacle 
connection type NEMA 14‐50R able to support a 
load of at least 30 A (per line) according to local 
code requirements. For four or three wires power 
supply connection system see diagram below. 
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
 
Check  your  local  code  for  which  of  the  options 
below    should  be  used    in  grounding  the 
receptacle power supply connections. 
OPTION 1 – FOUR Wires connection:
‐  Connect  the  L1  receptacle  terminal  to  the 
incoming  BLACK  electrical  supply  wire  (L1‐hot 
wire) 
‐  Connect  the  L2  receptacle  terminal  to  the 
incoming  RED  electrical  supply  wire  (L2‐hot 
wire) 
‐  Connect  the  NEUTRAL  receptacle  terminal  to 
the  incoming  NEUTRAL  (WHITE)  electrical 
supply wire 
‐  Connect  the  GROUND  receptacle  terminal  to 
the  incoming  GROUND  (GREEN)  electrical 
supply wire 
OPTION 2 - THREE-Wires connection:
‐  Connect  the  L1  receptacle  terminal  to  the 
incoming  BLACK  electrical  supply  wire  (L1‐hot 
wire) 
‐  Connect  the  L2  receptacle  terminal  to  the 
incoming  RED  electrical  supply  wire  (L2‐hot 
wire) 
‐  Connect  the  NEUTRAL  with  the  GROUND 
receptacle  terminal  to  the  incoming  NEUTRAL 
(WHITE) electrical supply wire 
DO NOT USE EXTENSION CORDS WITH THIS
APPLIANCE AS IT MAY RESULT IN FIRE,
ELECTRIC
PERSONAL INJURY.
The  appliance  is equipped  at  the  factory  with  an 
electric  supply  cord  set  4  wires  type  with  ring 
terminals  (L1,  L2,  N,  Ground)  suitable  for  range 
use  UL/CSA  listed  type  SRDT/DRT  2x6AWG  (L1, 
L2)+2x8AWG  (N,  G)  rated  300V,  40  or  50A  with 
fused  plug  type  NEMA  14‐50P;  cable  length  1,5 
m.; in case the supply cord set must be replaced, 
it  shall  be  replaced  with  an identical  set  having 
the  same  technical  specs  and  following carefully 
the  instructions and diagrams below: 
1)   Disconnect  appliance  from  electrical  power 
supply receptacle 
2)   Slide out the appliance from installation place 
to access to back enclosure panel 
3)   Remove  back  enclosure  panel  by  removing 
the 6 screws as shown below 
 
14
SHOCK
OR
OTHER
type
of
 