/ Electrical connection

FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options be-
low should be used in grounding the receptacle
power supply connections.
OPTION 1 – FOUR Wires connection:
-Connect the L1 receptacle terminal to the inco-
ming BLACK electrical supply wire (L1-hot wire)
-Connect the L2 receptacle terminal to the inco-
ming RED electrical supply wire (L2-hot wire)
-Connect the NEUTRAL receptacle terminal to
the incoming NEUTRAL (WHITE) electrical sup-
ply wire
-Connect the GROUND receptacle terminal to the
incoming GROUND (GREEN) electrical supply
wire
OPTION 2 - THREE-Wires connection:
-Connect the L1 receptacle terminal to the inco-
ming BLACK electrical supply wire (L1-hot wire)
-Connect the L2 receptacle terminal to the inco-
ming RED electrical supply wire (L2-hot wire)
-Connect the NEUTRAL with the GROUND recep-
tacle terminal to the incoming NEUTRAL (WHITE)
electrical supply wire
DO NOT USE EXTENSION CORDS WITH
THIS APPLIANCE AS IT MAY RESULT IN FIRE,
ELECTRIC SHOCK OR OTHER type of PERSO-
NAL INJURY.
10
The appliance is equipped at the factory with
an electric supply cord set 4 wires type with ring
terminals (L1, L2, N, Ground) suitable for range
use UL/CSA listed type SRDT/DRT 2x6AWG (L1,
L2)+2x8AWG (N, G) rated 300V, 40 or 50A with
fused plug type NEMA 14-50P; cable length 1,5
m.; in case the supply cord set must be replaced,
it shall be replaced with an identical set having the
same technical specs and following carefully the
instructions and diagrams below: