Electrical Connection; Electrical Grounding - Bertazzoni Master Series Installation, User And Maintenance Manual

Freestanding electric ranges, induction worktop, electric manual clean oven
Hide thumbs Also See for Master Series:
Table of Contents

Advertisement

ELECTRICAL CONNECTION

WARNING
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the
circuit breaker box or fuse box before
installing the appliance.
Provide appropriate ground for the
appliance.
Use copper conductors only.
Failure to follow these instructions
could result in serious injury or death.

ELECTRICAL GROUNDING

This appliance is equipped with a three-prong plug for your
protection against shock hazard and should be plugged
directly into a properly grounded socket. Do not cut or
remove the grounding prong from this plug.
CAUTION
Label all wires prior to disconnecting
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation after
servicing.
The appliance shall be connected to a single phase electric
line rated at 120/208Vac or 120/240Vac and 60Hz
frequency.
TYPE
VOLTAGE
36" IND
120/208V
DFM
120/240V
Install a suitable electric power supply receptacle
connection type NEMA 14-50R able to support a load of at
least 30 A (per line) according to local code requirements.
For four or three wires power supply connection system
see diagram below.
16
CIRCUIT
ELECTRI-
RATING
CAL
SUPPLY
14000W
40A
62A
14800W
40A
64A
Fig. 7 FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options below
should be used in grounding the receptacle power supply
connections.