ELECTRICAL CONNECTION

WARNING
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the
circuit breaker box or fuse box before
installing the appliance.
Provide appropriate ground for the
appliance.
Use copper conductors only.
Failure to follow these instructions
could result in serious injury or death.

ELECTRICAL GROUNDING

This appliance is equipped with a three-prong plug for your
protection against shock hazard and should be plugged
directly into a properly grounded socket. Do not cut or
remove the grounding prong from this plug.
CAUTION
Label all wires prior to disconnecting
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation after
servicing.
The appliance shall be connected to a single phase electric
line rated at 120/208Vac or 120/240Vac and 60Hz
frequency.
TYPE
VOLTAGE
30" IND
120/208V
DFS
120/240V
Install a suitable electric power supply receptacle
connection type NEMA 14-50R able to support a load of at
least 30 A (per line) according to local code requirements.
For four or three wires power supply connection system
see diagram below.
16
CIRCUIT
ELECTRI-
RATING
CAL
SUPPLY
11700W
40A
53A
13000W
40A
56A
Fig. 7 FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options below
should be used in grounding the receptacle power supply
connections.