CBX ELECTRICAL CONNECTIONS
4.3.2 ID-NET™ Response Time
The following figure shows the response time of the ID-NET™ network. This time is defined
as the period between the Trigger activation and the beginning of data transmission to the
Host.
240
220
200
180
160
140
120
100
80
60
40
20
0
0
CONDITIONS:
ID-NET™ M/S Synchronized layout
message length = 50 bytes per node
Max ID-NET™ Response Time
1
2
3
4
5
6
Number of Nodes
500 kbps
Figure 27 – ID-NET™ Response Time
7
8
9
10
11
12
250 kbps
13
14 15
16
125 kbps