4.5 INPUTS

There are two optocoupled polarity insensitive inputs available on the scanner: Input 1
(External Trigger) and Input 2, a generic input:
The electrical features of both inputs are:
Maximum voltage:
Maximum current:
An anti-disturbance filter is implemented in software on both inputs so that the minimum
pulse duration is ≅ 5 milliseconds. This value can be increased through the software
parameter Debounce Filter, see the "2K/4K Family Software Configuration Parameter Guide"
Help file".
CBX100/500
+V
I1A
I1B
-V
The External Trigger input is used in the On-Line operating Mode and tells the scanner to
scan for a code. The active state of this input is selected in software. Refer to the Genius™
Help On Line.
The yellow Trigger LED
corresponds to ON.
This input is optocoupled and can be driven by both an NPN and PNP type command. The
connections are indicated in the following diagrams:
EXTERNAL TRIGGER INPUT CONNECTIONS USING DS2100N POWER
Figure 33 – PH-1 (PNP) External Trigger Using DS2100N Power
42
30 Vdc
12 mA (scanner) + 12 mA (CBX)
Function
Power Source - External Trigger
External Trigger A (polarity insensitive)
External Trigger B (polarity insensitive)
Power Reference - External Trigger
(Figure
A, 3) is on when the active state of the External Trigger
DS2100N REFERENCE MANUAL
PH-1 Photocell (PNP)
(brown)
(black)
(blue)