Reset Scanner to Factory Default
If it ever becomes necessary to reset the scanner to the factory default values, you can
perform this procedure by holding the X-PRESS™ push button pressed while powering up
the scanner. At the end of the procedure (about 5-6 seconds), the Configuration and
Environmental parameters are reset, all LEDs blink simultaneously 3 times and the message
"Default Set" is shown on the display.

2.4 MODEL DESCRIPTION

The DS2100N scanner is available in versions that differ in regard to the following
parameters:
Resolution
Performance
Linear or raster reading
Optical Resolution
1 = Standard resolution
2 = High resolution
The following tables display each version's reading performance.
Version
Version
12X0
12X4
22X0
2XX4
See reading diagrams in par. 7.4 for further details.
22
DS2100N - X X X X
Communication Interface
2= RS232/RS485main + RS232 aux
+ RS485 ID-NET™
Max Code Resolution
mm (mils)
12X0
0.20 (8)
12X4
0.15 (6)
22X0
0.15 (6)
22X4
0.12 (5)
40 mm (1.6 in) - 300 mm (11.8 in) on 0.50mm (20 mils) codes
50 mm (1.8 in) - 310 mm (11.8 in) on 0.50 mm (20 mils) codes
30 mm (1.2 in) - 90 mm (3.5 in) on 0.30 mm (12 mils) codes
45 mm (1.8) – 100 mm (3.9 in) on 0.20 mm (8 mils) codes
DS2100N REFERENCE MANUAL
Optic Version
0 = Linear
1 = Raster R1
scans/s
500 to 800
800 to 1000
500 to 800
800 to 1000
Reading Distance
Performance
0 = Standard
4 = High Performance